Trace 1300 Modular Concept

  • Injector modules include injector body, electronics for temperature and carrier gas control.
  • Up to 2 injector module (front and back) can be installed.
  • A 2 minutes operation versus several hours operation of any other laboratory GC on the market
 

Helium Saver Module

Helium Saver technology and Module Revolutionary, Unique, Patented Features and Benefits

Up to 14 years of one helium cylinder life time

 

  • Always saves works during analytical run and idle time
  • Always ready no switch-back equilibration time
  • Can have two Helium Saver Modules installed
  • Can have hydrogen carrier on the same system’s 2nd channel
  • Change septum and liner without GC or MS cooling down

iC-SSL Injector

  • Easy plug-in with the "Instantaneously Connected" Thermo proprietary technology
  • integrated electronic gas control (IEC)
  • Max T = 400°C
  • split ratio up to 12500:1
  • Control of split flow in 1mL/min from 0 to 1250 mL/min
  • Purge flow from 0 to 50 ml/min (electronic control)
  • Suitable for all capillary columns (50 μm to 530 μm id)
  • Compatible with 1/8" and 1/16"  packed column using adapters
  • Supports P&T/TD/.. by special adapter
  • Compatible Merlin Microseal® septum

iC-PTV Injector

  • Easy plug-in with the "Instantaneously Connected" Thermo proprietary technology
  • Integrated electronic gas control (IEC)
  • T programming up to 870 °C/min (up to 3 ramps)
    -100 °C with LiqN2, -50 °C with CO2
  • Max T = 450°C
  • split ratio up to 12500:1
  • Control of split flow in 1mL/min from 0 to 1250 mL/min
  • Purge flow from 0 to 50 ml/min (electronic control)
  • supports On Column (TPOC) using special liner
  • compatible Merlin Microseal® septum

iC-GSV Module

Instant Connect Gas Sampling Valve

 

  • Sampling loops: 20 µL, 50 µL, 100 µL, 250 µL (as standard), 500 µL and 1 mL
  • Suitable for all capillary columns (50 µm to 530 µm i.d.)
  • Compatible with 1/8" and 1/16" packed column using adapters
  • Maximum temperature: 150 °C
  • Switching from load sample to inject sample position (and vice-versa) is controlled through the user Interface

iC-ThermoSpray SSL Injector

  • Easy plug-in with the "Instantaneously Connected" Thermo proprietary technology
  • The Thermospray SSL injector is used for split, splitless, or surged splitless injections
  • Flow from 0.01–100 mL/min
  • Inlet temperature in the range of 0-400 °C
  • Split Flow from 5-1250 mL/min.
  • Splitless Time from 0.00-999.99 min.lit
  • Ratio = (split flow) / (column flow) from 1-12500.

 

iC-On-Column Injector

  • Easy plug-in with the "Instantaneously Connected" Thermo proprietary technology
  • With the on-column injector, you use a syringe to inject a liquid sample directly into the
  • capillary column
  • On-column injection is the direct, cold injection of a liquid sample into the column at a point
  • within the column oven and under oven temperature control.
  • The on-column injector requires an auxiliary gas module and an auxiliary temperature module.