Trace 1300 Modular Concept

  • Detector modules include cell, electronics for temperature and auxiliary gas control, signal amplifier and A/D conversion
  • Up to 2 detector module (front and back) can be installed
  • A 2 minutes operation versus several hours operation of any other laboratory GC on the market
 

iC-FID Detector

  • Easy plug-in with the "Instantaneously Connected" Thermo proprietary technology
  • integrated electronic gas control (IEC)
  • control flows: Air: 0-500 ml/min; H2 0-100 ml/min; makeup (N2 or He) 0-50 ml/min
  • capillary column optimized compatible with 1/8" and 1/16"   packed column
  • Flameout detection and automatic re-ignition
  • Max T = 450 °C (steps of 0.1 °C)
  • MDL < 1.8 pg C/
  • sensitivity > 0.03 Coulombs/gC
  • linear dynamic range = >107 (± 10%)
  • Acquisition rate up to 300 Hz
  • He or N2 as make-up gas.

iC-TCD Detector

  • easy plug-in with the "Instantaneously Connected" Thermo proprietary technology
  • micro-volume Ni/Fe cell
  • integrated electronic gas control (IEC)
  • reference gas not required
  • make-up gas from 0 to 5 ml/min
  • capillary column optimized (micro TCD) compatible with 1/8" and 1/16"   packed column
  • Max T = 400 °C
  • MDL = <400 pg tridecane/ml with He carrier or <20 pg tridecane/s with a total flow through the cell of 3 ml/min
  • Linear dynamic range= 105
  • acquisition rate up to 300 Hz.

iC-ECD Detector

  • easy plug-in with the "Instantaneously Connected" Thermo proprietary technology
  • miniaturized cell, with purged removable anode
  • integrated electronic gas control (IEC)
  • make-up (nitrogen or 95%argon/5% methane) control flow from  0 to 500 ml/min
  • Max T = 400 °C
  • MDL < 5 fg/s lindane
  • linear dynamic range > 104 with lindane
  • acquisition rate up to 300 Hz
  • radioactive source 370 MBq equal to 10 mCi, 63Ni

iC-NPD Detector

  • easy plug-in with the "Instantaneously Connected" Thermo proprietary technology
  • integrated electronic gas control (IEC)
  • control flows: Air: 0 to 500 mL/min, H2: 0 to 10 mL/min. Make-up gas (N2): 0 to 50 mL/min
  • Max T = 450 °C
  • includes TID-2 ceramic bead
  • available also TID-4 ceramic bead
  • Compatible with BLOS (Agilent) glass beads
  • MDL < 20 fg P/s and < 100 fg N/s with standard ceramic bead
  • selectivity gP/gC = 200000
  • selectivity gN/gC = 80000
  • linear dynamic range = 104
  • Acquisition rate up to 300 Hz.
  • External power supply

iC-FPD Detector

  • Minimum detectable amount: 100 fg P/s and 5 pg S/s (Methyl Parathion)
  • Dynamic range: 104 (P), >103 (S)
  • Selectivity: P/C = 106:1, and S/C=106:1
  • Maximum temperature: 450 °C base temperature, 200 °C cell temperature; in steps of 0.1 °C
  • Also available in dual wavelength version