LC-GC 9000

Combining the power of HPLC and GC

LC-GC 9000

Both GC and LC are widely used in today’s analytical lab. Each technique has its advantages. In recent years
HPLC has increased in range of application mostly because shorter sample preparation.

Yet GC still offers the best sensitivity and separation power.
The coupling of LC to GC offers the best of both world:

  • Simple sample preparation
  • Sample enrichment
  • High resolution of compounds
  • High sensitivity


In LC-GC technique, the sample is separated using typically NPLC (Normal Phase Liquid Chromatography).
The LC allows selective isolation of groups of compounds then transfer to the GC by mean of on-column large volume injection.

Following a long tradition of chromatography innovation and experience,
Brechbühler AG now commercializes Thermo’s LC-GC System.
Brechbühler brings exciting enhancement to the technique as well as its knowledge and excellent customer support.

 

LC-GC-MS

Q Exactive™ GC hybrid quadrupole Orbitrap mass spectrometer coupled with on-line LC-GC 9000 System


Technique

LC-GC Technique

The principle of the LC-GC coupling is simple

 

After separation on the LC column the fraction of interest is transferred via the transfer valve onto the GC column by large volume injection technique. The fraction transferred is analyzed by the GC or GC/MS. A backflush of the LC column can be performed at any time. Because of large volume injection the sensitivity is greatly improved


Schematics LC-GC 9000

Automation at your fingertip

The dedicated software makes the LC-GC 9000 a routine instrument. Once the method is setup, a sequence of sample can be programmed. The software controls all the instruments (Phoenix pump, Trace GC, PAL Autosampler and Exachrom acquisition system).

LC-GC Software

Mode of operation

Standard mode:
one transfer per LC run

 

Multitransfer mode:
Several transfer per LC Run. The pumps are placed on Hold after each transfer for the duration of the GC run. This mode can be used for LCxGC experiments

 

Peak detection transfer:
The transfer is triggered by the detection of a peak on the UV detector.


Dual channel transfer

The LC-GC 9000 system is now capable of dual channel transfer on a same LC run.The Switching (or auxiliary) valve is configured as a second transfer valve for the 2nd channel. 

 

The Trace 13XX GC already equipped with the auxiliary carrier and valve and temperature control module is fitted with a second Solvent Vapor Exit (SVE) valve.

 

The LC-GC Software has been modified to include an additional parameter for the amount of the MOAH internal standard amount. This amount is sent to Chromeleon for calculation. Reports have been modified to include both MOSH and MOAH data.

LC-GC Dual channel MOSH MOAH

For complex matrices

LC-GC coupling has been successfully used in the following fields:

 

  • Food samples
  • Flavor & Fragrance samples
  • Petrochemical and industrial samples
  • Environmental samples
  • Pharmaceutical samples
  • Biological samples.

 

Any sample in complex matrices.

 

There are many applications published using LC-GC techniques.
For more information on the technique please refer to Dr.. K. Grob & Maurus Biedermann work.
Another good starting point is a paper by Luigi Mondelo: On-line Coupled LC–GC: Theory and Applications

Esters in extra virgin olive oil data courtesy of Maurus Biedermann (KLZH)


Visit us on Facebook
Visit us on Youtube
Visit us on Twitter
Visit us on LinkedIn

Contact

Send E-Mail

Schlieren:

Tel +41 44 732 31 31

Fax +41 43 260 95 36

Echallens:

Tel +41 21 625 58 10

Fax +41 43 260 95 36


Contact China

SUN-SCI

Shenzhen Sun Scientific Equipment CO,Ltd 

Mabian BLD liuxian RD2 BaoAn Shenzhen China 

Tel: +8675586136373 

Send E-Mail to SUN-SCI

 

 

 
Downloads

Mineraloil in Food